C. TROUBLESHOOTING
C.1 Error codes
Overview
When the error code is preceded by a '-' sign, then the error means a real error for the projector.
When the error code is preceded by a '+' sign, then the error code means a warning. The projector does not fail yet, but take care
for the warning and try to resolve the problem. A warning state can turn into an error state.
Not all error codes can have two states. When the state is available, it is indicated by a Yes in the overview table. When the state
is not available, it is indicated by a No.
Error
Description
code
2000
No lps
detected
4199
FIB reset
failed
1697
Formatter init
failed
1696
Formatter ctrl
init failed
1695
Red form.
start failed
1694
Green form.
start failed
1693
Blue form.
start failed
1692
Form.
PWRGood
1000
Wrong lamp
parameters
1017
2002
Lamp start
failed
2201
PFC start
failed
2501
PFC start
failed
2801
PFC start
failed
2202
LPS start
failed
2502
LPS start
failed
2802
LPS start
failed
R5976921 FLM R20+ PERFORMER 08/03/2006
Error
Warn-
Caused by
ing
-
Yes
no communication with lamp power
supply
-
Yes
no communication with FIB
-
Yes
no communication with formatter
ctrl
-
Yes
no communication with formatter
ctrl
-
Yes
no communication with red
formatter
-
Yes
no communication with green
formatter
-
Yes
no communication with blue
formatter
-
Yes
formatter 'Power Good' signal not
OK
-
Yes
Wrong lamp/ no communication
with lamp
-
Yes
Hot restrike
Lamp with many strikes
maximum run time exceeded
Lamp or LPS or SPG failed
-
Yes
LPS (address 0x20)
-
Yes
LPS (address 0x22)
-
Yes
LPS (address 0x28)
-
Yes
-
Yes
-
Yes
C. Troubleshooting
Action
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Check lamp type
Call a qualified service engineer
Let cool down the lamp for at least
5 minutes. Retry a few times.
Replace the lamp with a new one
Replace LPS or SPG or cabling.
Replace LPS
Replace LPS
Replace LPS
Replace LPS
Replace LPS
Replace LPS