Troubleshooting Checklist - Barco F70 Service Manual

Hide thumbs Also See for F70:
Table of Contents

Advertisement

Physical sub location
Can be sensor number, bank number, coordinate, ID, ...
Physical sub location
0..FFFh
Optional indicator
Optional indicator
High
Low
Type
Type
Description
INFO
Messages of this type informs the user about an
event or status change.
WARN-
Messages of this type warns the user that system
ING
performance will be impacted and/or stability/
safety could be compromised if no corrective
action is taken.
ERROR Messages of this type alerts the user that system
performance or image quality (including no
image) is visibly impacted and/or stability/safety
is compromised.
Only error and warning messages are enumerated in the troubleshooting list below.

16.4.2 Troubleshooting checklist

Code E0000000: "Environment temperature too low" (Error)
Situation
Ambient temperature too low.
Code E0000001: "Environment temperature exceeded" (Error)
Situation
Ambient temperature too high.
Code E0000101: "Mainboard sensor temperature exceeded" (Error)
Situation
Main board is not sufficiently
cooled.
Code E0000201: "Mainboard IMX temperature exceeded" (Error)
For this error the same troubleshooting table can be applied to as for code E0000101: "Mainboard sensor
temperature exceeded".
Value
01h
00h
Solution
Make sure the projector operates within specs and make sure that the
installation requirements are fulfilled.
Solution
Check the ambient temperature at the front air inlets of the projector.
Check airflow of the projector.
Make sure the projector operates within specs and make sure that the
installation requirements are fulfilled.
Solution
Check environmental conditions.
Check whether fans on main board are running as expected.
Comments
Note / Recommendation
An action by the user to resolve the issue is
advised.
An immediate action by the user is required.
Troubleshooting
723–0018 /02
F70
89