Mitsubishi Electric MELSEC iQ-F Series User Manual page 85

Programmable controller
Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

Item
Device
Device Name
Designation
Number
Link Parameters
Active Configuration
Comment
Network
IP Address
Properties
Description
*3
Ping
[Ping] button
Loop
Stop on Error
[Clear] button
Ping Result
*1 Characters from A to Z, numbers from 0 to 9, "." (dot), "-" (hyphen), and "_" (underscore) can be used. For the first character of a name,
only characters from A to Z can be used.
*2 Cannot be set to a value from 127.0.0.0 to 127.255.255.255.
*3 Can be selected when EtherNet/IP Configuration Tool for FX5-ENET/IP is switched to the online state. (Page 56 File)
When an EtherNet/IP device has been added by "Network Detection", its IP address is registered
automatically. When an EtherNet/IP device has been added from "Device Library", manually enter its IP
address.
For the operations on "Network Detection" and "Device Library", refer to the following.
• Page 67 Network Detection
• Page 65 Device Library
Description
Sets the name to use in management with EtherNet/IP Configuration
Tool for FX5-ENET/IP.
By default, names of EtherNet/IP devices not registered in the network
configuration setting are displayed in the form such as "DEVICE-A" and
"DEVICE-B".
Sets the control number of the EtherNet/IP device.
The control number that has not been set for EtherNet/IP devices can
be selected from the list.
Enables or disables the link between the IP address and the device
number of the EtherNet/IP device.
• Selected: Enabled
• Not selected: Disabled
Enable this item to link the device number of the EtherNet/IP device to
the fourth octet of the IP address.
Enables or disables the parameters set for the EtherNet/IP device on
the FX5-ENET/IP.
• Selected: Enabled
• Not selected: Disabled
Disable this item when the parameters of the EtherNet/IP device need
to be deleted from the FX5-ENET/IP with the settings in EtherNet/IP
Configuration Tool for FX5-ENET/IP held.
Displays the comment input field.
Information about the EtherNet/IP device is described with the default
setting.
Specifies the IP address of the EtherNet/IP device.
Displays the description of the selected item.
Pings the specified EtherNet/IP device.
Select this check box to repeatedly ping the device once every 100 ms.
Sets whether to interrupt pinging if an error occurs when the "Loop"
check box is selected.
• Selected: Pinging will be interrupted if an error occurs.
• Not selected: Pinging will continue even if an error occurs.
Deletes the content of "Ping Result".
Displays the result of pinging.
Setting range
Up to 50 characters
(Default: Refer to the left.)
0 to 32
(Default: Minimum value of
the control numbers of
EtherNet/IP devices that
have not been set.)
• Selected
• Not selected
(Default: Not selected)
• Selected
• Not selected
(Default: Selected)
Up to 255 single-byte
characters
(Default: Varies depending
on the EtherNet/IP device)
1.0.0.1 to 223.255.255.254
(Default: Current IP address
of the EtherNet/IP device)
• Selected
• Not selected
(Default: Not selected)
• Selected
• Not selected
(Default: Not selected)
8 EtherNet/IP Configuration Tool for FX5-ENET/IP
8.1 Window Structure
*1
*2
8
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx5-enet/ip

Table of Contents