Event
Event
Event
code
type
category
2DA9
System
Error
2DAA
System
Error
2DB0
System
Error
3030
System
Error
3040
System
Error
3041
System
Error
3042
System
Error
3050
System
Error
3052
System
Error
3053
System
Error
3055
System
Error
3056
System
Error
3095
System
Error
3096
System
Error
3097
System
Error
3098
System
Error
3099
System
Error
309A
System
Error
309B
System
Error
309C
System
Error
309D
System
Error
309E
System
Error
309F
System
Error
3CF1
System
Error
3E30
System
Error
3E31
System
Error
3E32
System
Error
3E33
System
Error
Event
Detected event
status
Moderate
Connection setting parameter
(Communication data code error)
Moderate
Connection setting parameter (Error in
specification of writing during running)
Moderate
Request data error
Moderate
Specific code error
Moderate
Firmware update file version error
Moderate
Failure in verification of firmware
update file integrity
Moderate
Failure in acquisition of firmware
update file
Moderate
Socket communication fails
Moderate
Link-down
Moderate
Timeout
Moderate
Receive error
Moderate
Socket communication buffer full
Moderate
The number of target IP address setting
is outside the range (IP filter settings)
Moderate
IP address 1 is outside the range (IP
filter settings)
Moderate
IP address 2 is outside the range (IP
filter settings)
IP address 1 ≥ IP address 2 error (IP
Moderate
filter settings)
Moderate
The number of excluded IP address
setting is outside the range (IP filter
settings)
Moderate
The target IP address setting number is
outside the range (IP filter settings)
Moderate
The excluded IP address number is
outside the range (IP filter settings)
Moderate
The excluded IP address is outside the
range (IP filter settings)
Moderate
Target module support error (IP
address settings parameter)
Moderate
Target module support error (Gateway
address setting parameter)
Moderate
The gateway address (IPv6) is outside
the range (Gateway address setting
parameter)
Major
BINT disconnection detection timeout
error
Major
The fixed memory block acquisition/
release ID number is invalid
Major
Fixed memory block acquisition/release
context error
Major
Error in forced cancellation of waiting
for variable memory block acquisition/
release
Major
Error in forced cancellation of waiting
due to reset of fixed memory block
acquisition/release object
Detailed information
Detailed
Detailed
information 1
information 2
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
10 TROUBLESHOOTING
10.7 List of Event Code
Detailed
information 3
Failure
information
Failure
10
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
131