Open request signal
■Open request signal (Un\G154 to Un\G155)
Open request signal for each connection number of socket communication.
Address
bit
Un\G154
b0
b1
b15
Un\G155
b0 to b15
Socket communications receive status signal
■Socket communications receive status signal (Un\G156 to Un\G157)
Socket communication receive state signal for each connection number.
Address
bit
Un\G156
b0
b1
b15
Un\G157
b0 to b15
Initial status
■Initial status (Un\G158)
You can confirm whether or not FX5-ENET/IP has been initialized.
Address
bit
Un\G158
b0
b1
Initial error code
■Initial error code (Un\G159)
The error codes that occur during initialization of FX5-ENET/IP are stored. (0 is stored when communications are normal.)
For details on error code, refer to Page 126 Module error.
Same IP address state storage area
■Same IP address state storage area (Un\G201)
Same IP address state is stored.
Address
bit
Un\G201
b0
APPX
144
Appendix 4 Buffer Memory
Connection number
Connection number 1
Connection number 2
Connection number 16
Connection number 17 to 32
Connection number
Connection number 1
Connection number 2
Connection number 16
Connection number 17 to 32
Name
Initial normal completion status
Initial abnormal completion status
Name
Same IP address detection flag
Description
• On: Requesting open
• Off: No open request
Description
• On: Data reception completed
• Off: Data not received
Description
Turns on when the initialization is normally completed.
Turns on when the initialization is abnormally completed.
Description
Turns ON if there is a same IP address.