Configure Alarm Output - HIKVISION DS-7608NXI-I2/8P/4S User Manual

Hide thumbs Also See for DS-7608NXI-I2/8P/4S:
Table of Contents

Advertisement

6) Select the alarm linkage action(s) you want to disarm for local alarm input 1.
When the alarm input 1 (Local<-1) is enabled with one-key disarming, the other alarm input settings
are not configurable.
7) Click Apply to save the settings.

Configure Alarm Output

Trigger an alarm output when an alarm is triggered.
1) Go to System > Event > Normal Event > Alarm Output.
2) Select an alarm output item from the list and click
3) Edit the alarm name.
4) Select the dwell time (the alarm duration) from 5s to 600s, or Manually Clear.
4) Manually Clear: you should manually clear the alarm when the alarm occurs. Refer to
Trigger or Clear Alarm Output Manually
5) Set the arming schedule. Refer to
Figure 11-8 One-Key Alarm Disarming
for detailed instructions.
Chapter 11.1 Configure Arming Schedule
DS-76xx-I2/xP/4S NVR UM
.
.
Chapter 11.8
97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds-7616nxi-i2/16p/4s

Table of Contents