Technical Data - ESAB Aristo Mig 3001i Service Manual

Hide thumbs Also See for Aristo Mig 3001i:
Table of Contents

Advertisement

TECHNICAL DATA

Mains voltage
Mains supply
Primary current
I
MIG/MAG
max
I
TIG
max
I
MMA
max
No-load power demand when in the
energy-saving mode, 6.5 min. after
welding
Setting range
MIG/MAG
TIG
MMA
Permissible load at MIG/MAG
35 % duty cycle
60 % duty cycle
100% duty cycle
Permissible load at TIG
35 % duty cycle
60 % duty cycle
100% duty cycle
Permissible load at MMA
30 % duty cycle
60 % duty cycle
100% duty cycle
Power factor at maximum current
MIG/MAG
TIG
MMA
Efficiency at maximum current
MIG/MAG
TIG
MMA
Open-circuit voltage
without VRD function
VRD function deactivated
VRD function activated
Operating temperature
Transportation temperature
Continual sound pressure at no-load
Dimensions lxwxh
with cooling unit
Weight
with cooling unit
Insulation class transformer
Enclosure class
Application class
1) Valid for power sources without VRD specification on the rating plate.
ca41_00
400 V $10%, 3 ∼ 50/60 Hz 400 V $10%, 3 ∼ 50/60 Hz
S
sc min
16 A
13 A
19 A
30 W
16 A / 8 V - 300 A / 48 V
4 - 300 A
16 - 300 A
300 A / 29 V
240 A / 26 V
200 A / 24 V
300 A / 22 V
240 A / 19.6 V
200 A / 18 V
300 A / 32 V
230 A / 29.2 V
190 A / 27.6 V
0.90
0.89
0.90
85 %
82%
84 %
1)
67 V DC
2)
60 V DC
2)
< 35 V
-10 to +40° C
-20 to +55° C
<70 db (A)
652 x 249 x 423 mm
714 x 249 x 693 mm
33 kg
53.5 kg
H
IP23
Mig 3001i
1.4 MVA
S
13 A
19 A
30 W
4 - 300 A
16 - 300 A
300 A / 22 V
240 A / 19.6 V
200 A / 18 V
300 A / 32 V
230 A / 29.2 V
190 A / 27.6 V
0.89
0.90
81%
84 %
67 V DC
60 V DC
< 35 V
-10 to +40° C
-20 to +55° C
<70 db (A)
652 x 249 x 423 mm
714 x 249 x 693 mm
33.5 kg
54 kg
H
IP23
- 6 -
Tig 3001i
1.4 MVA
sc min
S0740 800 196/E101019/P76

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Origo tig 3001i