2) Valid for power sources with VRD specification on the rating plate. The VRD function is explained in
the instruction manual for the control panel, if the control panel has this function.
Mains supply, S
sc min
Minimum short circuit power on the network in accordance with IEC 61000-3-12
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld at a cer­
tain load without overloading. The duty cycle is valid for 40° C.
The duty cycle is valid for 40° C.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
ca41_00
- 7 -
S0740 800 196/E101019/P76

Hide quick links: