3   TECHNICAL DATA
3

TECHNICAL DATA

Voltage
Primary current
I
GMAW - MIG
max.
I
GTAW - TIG
max.
I
SMAW - Stick
max.
I
GMAW - MIG
eff.
I
GTAW - TIG
eff.
I
SMAW - Stick
eff.
Permissible load at GMAW - MIG
100% duty cycle
60% duty cycle
40% duty cycle
25% duty cycle
20% duty cycle
15% duty cycle
Setting range (DC)
Permissible load at GTAW - TIG
100% duty cycle
60% duty cycle
40% duty cycle
30% duty cycle
20% duty cycle
Setting range (DC)
Permissible load at SMAW - Stick
100% duty cycle
60% duty cycle
40% duty cycle
25% duty cycle
20% duty cycle
Setting range (DC)
Open circuit voltage (OCV)
VRD deactivated
0463 789 001
120 V, 1 ~ 50/60 Hz
Breaker 20 A: 28.6 A
Breaker 15 A: 20.8 A
Breaker 15 A: 20.8 A
Breaker 15 A: 20.8 A
Breaker 20 A: 18.0 A
Breaker 15 A: 14.7 A
Breaker 15 A: 14.7 A
Breaker 15 A: 14.7 A
Breaker 15 A: 75 A / 17.75 V
Breaker 20 A: 90 A / 18.5 V
Breaker 15 A: 90 A / 18.5 V
Breaker 20 A: 110 A / 19.5 V
Breaker 15 A: 100 A / 19 V
-
Breaker 20 A: 130 A / 20.5 V
-
15 A / 14.75 V – 130 A / 20.5 V
100 A / 14 V
120 A / 14.8 V
130 A / 15.2 V
-
-
5 A / 10.2 V – 130 A / 15.2 V
65 A / 22.6 V
80 A / 23.2 V
85 A / 23.4 V
-
130 A / 25.2 V
6 A / 20.6 V – 130 A / 25.2 V
52 V
- 12 -
Rebel EMP 215ic
230 V, 1 ~ 50/60 Hz
30 A (27.6 A at 25% duty cycle)
19 A
25 A
14 A
10 A
13 A
110 A / 19.5 V
125 A / 20.25 V
150 A / 21.5 V
205 A / 24.25 V
-
235 A / 26 A
15 A / 14.75 V – 235 A / 26.0 V
110 A / 14.4 V
125 A / 15 V
-
180 A / 17.2 V
200 A / 18 V
5 A / 10.2 V – 200 A / 18 V
100 A / 24 V
125 A / 25 V
-
180 A / 27.2 V
-
16 A / 20.6 V – 180 A / 27.2 V
52 V