Technical Data - ESAB Rogue EMP 210 PRO Instruction Manual

Table of Contents

Advertisement

3   TECHNICAL DATA
3

TECHNICAL DATA

Outlet voltage
Primary current
I
GMAW - MIG
max
I
GTAW - TIG
max
I
SMAW - MMA
max
I
GMAW - MIG
eff
I
GTAW - TIG
eff
I
SMAW - MMA
eff
No-load power demand when in energy saving mode
Setting range
GMAW
GTAW
SMAW
Permissible load at GMAW - MIG
25 % duty cycle
60 % duty cycle
100% duty cycle
Permissible load at GTAW - TIG
25 % duty cycle
60 % duty cycle
100% duty cycle
Permissible load at SMAW - MMA
25 % duty cycle
60 % duty cycle
100% duty cycle
Power factor at maximum current
GMAW
GTAW
SMAW
Efficiency at maximum current
GMAW
GTAW
SMAW
Open-circuit voltage U
(VRD 35 V deactivated)
Operating temperature
0447 978 001
max
0
Rogue EMP 210 PRO
230 V 1~ 50/60 Hz
30 A/15.5 V ~ 210 A/24.5 V
10 A/10.4 V ~ 210 A/18.4 V
10 A/20.4 V ~ 180 A/27.2 V
210 A/24.5 V
136 A/20.8 V
105 A/19.2 V
210 A/18.0 V
136 A/15.4 V
105 A/14.2 V
180 A/27.2 V
116 A/24.7 V
-10 to +40°C (+14 to 104°F)
- 8 -
28 A
21 A
26 A
14 A
10.5 A
13 A
<50 W
90 A/23.6 V
0.99
0.99
0.99
>80 %
>80 %
>80 %
78 V
© ESAB AB 2023

Advertisement

Table of Contents
loading

Table of Contents