Fault-Tracing; Spare Parts - ESAB Aristo Mig 3001i Service Manual

Hide thumbs Also See for Aristo Mig 3001i:
Table of Contents

Advertisement

FAULT-TRACING

Try these recommended checks and inspections before sending for an authorized service
technician.
Type of fault
No arc
The welding current is
interrupted during
welding.
The overloading
protection trips
frequently.
Poor welding perform­
ance

SPARE PARTS

The spare parts list is published in a separate document that can be downloaded from the
internet: www.esab.com
Product
Filename
Mig 3001i
0459 839 031
Tig 3001i
0459 839 033
ca41i1
S
Check that the mains power supply switch is turned on.
S
Check that the welding and return cables are correctly connected.
S
Check that the correct current value is set.
S
Check the mains power supply fuses.
S
Check whether the overloading protection has tripped (indicated in the
control panel).
S
Check the mains power supply fuses.
S
Check to see whether the dust filter is clogged.
S
Make sure that you are not exceeding the rated data for the power
source (i.e. that the unit is not being overloaded).
S
Check that the welding and return cables are correctly connected.
S
Check that the correct current value is set.
S
Check that the correct wire or electrode is used.
S
Check the mains power supply fuses.
- 74 -
Corrective action
S0740 800 196/E101019/P76

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Origo tig 3001i

Table of Contents