Technical Data; Technical Data For Mains Mode - ESAB Renegade VOLT ES 200i Instruction Manual

Table of Contents

Advertisement

3   TECHNICAL DATA
3

TECHNICAL DATA

3.1

Technical data for Mains Mode

Outlet voltage
Primary current
I
1max
I
1eff
No-load power demand when in
energy-saving mode
Setting range
MMA / SMAW / Stick
TIG / GTAW
Permissible load at MMA / SMAW / Stick
25% duty cycle
60% duty cycle
100% duty cycle
Permissible load at TIG / GTAW
25% duty cycle
60% duty cycle
100% duty cycle
Apparent power I
at maximum
2
current
Active power I
at maximum current 3.3 kW
2
Power factor at maximum current
MMA / SMAW / Stick
TIG / GTAW
Efficiency at maximum current
MMA / SMAW / Stick
TIG / GTAW
Open-circuit voltage U
VRD deactivated
VRD activated
Operating temperature
Transportation temperature
Constant sound pressure when
idling
Dimensions l × w × h
0447 814 001
Renegade VOLT ES 200i
120 V ±15%,
1~ 50/60 Hz
27 A
13.5 A
<50 W
10-110 A
10-140 A
110 A / 24.4
70 A / 22.8 V
55 A / 22.2 V
140 A / 15.6 V
90 A / 13.6 V
70 A / 12.8 V
3.4 kVA
max
0
230 V ±15%,
1~ 50/60 Hz
28 A
14 A
<50 W
10-200 A
10-200 A
200 A / 28 V
129 A / 25.2 V
100 A / 24 V
200 A / 18 V
129 A / 15.2 V
100 A / 14 V
5.8 kVA
5.7 kW
0.99
0.99
82%
82%
80 V
<30 V
-10 to +40°C (+14 to 104°F)
-20 to +55°C (-4 to +161°F)
<70 db (A)
- 16 -