Make sure that the welding power source is connected to the correct supply voltage and
that it is protected by the correct fuse rating. A protective earth connection must be made in
accordance with regulations.
NOTE! The welding power source is designed for connection to a 400 volt system with four
conductors. If the power source is to be used in countries with a higher or lower supply voltage, the
power source must be connected via a safety transformer.
Recommended fuse sizes and minimum cable area
Mains voltage
Mains cable area mm
Phase current I
eff
Fuse
anti-surge
type C MCB
NOTE!
The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. Use the welding power source in accordance with the relevant national regulations.

OPERATION

General safety regulations for the handling of the equipment can be found in the instruction
manual. Read through before you start using the equipment!

Connections and control devices Mig 3001i

1
Connection for wire feed unit or remote
control unit
2
Connection (-) MIG/MAG: Return cable
TIG: Welding torch
MMA: Return cable or welding cable
3
Connection (+) MIG/MAG: Welding cable
TIG: Return cable
MMA: Welding cable or return cable
ca41i1
Mig 3001i
400 V 3 50 Hz
2
2
4G2.5 mm
10 A
16 A
16 A
Tig 3001i
400 V 3 50 Hz
2
4G2.5 mm
10 A
16 A
16 A
4
Mains voltage switch
5
Fuse for supply voltage to feeder unit,
42 V
6
Control panel,
see separate instruction manual
- 71 -
S0740 800 196/E101019/P76