Technical Data - ESAB ET 180iP Instruction Manual

Table of Contents

Advertisement

3   TECHNICAL DATA
3

TECHNICAL DATA

Outlet voltage
Primary current
I
max
No-load power demand when
inenergy-saving mode
Setting range
MMA
TIG
Permissible load at MMA
25 % duty cycle
60 % duty cycle
100% duty cycle
Permissible load at TIG
25 % duty cycle
60 % duty cycle
100% duty cycle
Apparent power I
at maximum
2
current
Active power I
at maximum
2
current
Power factor at maximum current
MMA
TIG
Efficiency at maximum current
MMA
TIG
Open-circuit voltage U
VRD 35 V deactivated
VRD 35 V activated
Operating temperature
Transportation temperature
Constant sound pressure
when idling
Dimensions l × w × h
Weight
Insulation class
0463 862 001
Renegade ET 180iP
230 V ±15%,
1~ 50/60 Hz
26 A
25 W
18 W
5-180 A
5-180 A
180 A / 27.2 V
116 A / 24.6 V
90 A / 23.6 V
180 A / 17.2 V
116 A / 14.6 V
90 A / 13.6 V
6.1 kVA
6 kW
84%
81%
max
0
460 × 200 × 320 mm (18.1×7.9×12.6 in.)
115 V ±15%,
230 V ±15%,
1~ 50/60 Hz
1~ 50/60 Hz
29 A
26 A
25 W
25 W
18 W
18 W
5-110 A
5-180 A
5-140 A
5-210 A
110 A / 24.4 V
180 A / 27.2 V
71 A / 22.8 V
116 A / 24.6 V
55 A / 22.2 V
90 A / 23.6 V
140 A / 15.6 V
210 A / 18.4 V
90 A / 13.6 V
135 A / 15.4 V
70 A / 12.8 V
105 A / 14.2 V
3.33 kVA
6.1 kVA
3.3 kW
6 kW
0.99
0.99
84%
81%
78 V
<30 V
-10 to +40°C (+14 to 104°F)
-20 to +55°C (-4 to +161°F)
<70 db
11 kg (24.3 lbs)
F
- 9 -
Renegade ET 210iP
115 V ±15%,
1~ 50/60 Hz
29 A
25 W
18 W
5-110 A
5-140 A
110 A / 24.4 V
71 A / 22.8 V
55 A / 22.2 V
140 A / 15.6 V
90 A / 13.6 V
70 A / 12.8 V
3.33 kVA
3.3 kW
84%
84%
81%
81%
© ESAB AB 2023

Advertisement

Table of Contents
loading

This manual is also suitable for:

Et 210ip

Table of Contents