Removing the Bedbar (continued)
Installing the Bedbar
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev A
3. Tip the cutting unit to expose the bedknife and support the rear of the cutting
unit; refer to
Supporting the Cutting Unit when Servicing (page
4. Loosen the lock nuts (item 7) on each bedbar pivot bolt.
5. Remove the two bedbar pivot bolts, two metal washers and four plastic
washers from the cutting unit side plates.
Contact with the reel, bedknife or other cutting unit parts can result
in personal injury. Use heavy gloves when handling the bedbar.
6. Remove the bedbar assembly from the cutting unit.
7. Inspect the nylon bushings and rubber bushings in the side plates for wear
or damage. Replace the bushings if necessary.
g226763
1.
Side plate
2.
Rubber bushing
3.
Nylon bushing
4.
Plastic washer (2 each)
Refer to
Figure 131
for this procedure.
1. If rubber bushing was removed from either side plate, apply grease to outside
surface of new bushing and install into side plate. The bushing should be
installed flush with the inside surface of the side plate.
2.
If removed, install the nylon bushings with flange facing outward.
3. Apply anti-seize lubricant to the threads and shank of each bedbar pivot bolt.
CAUTION
Figure 131
5.
Metal washer
6.
Bedbar
7.
Bedbar pivot bolt
8.
Lock nut
Page 7–7