Removing the Starter/Generator Assembly
g286730
1.
Engine frame assembly
2.
Cap screw
3.
Cap screw ( 2 each)
4.
Isolating mount – rear
5.
Lock nut (3 each)
Electrical System: Service and Repairs
6.
Cap screw
7.
Clamp
8.
Lock nut
9.
Flange nut (4 each)
10.
Wire harness connector
Refer to
Figure 80
for this procedure
1. Park the machine on a level surface, lower the cutting units, set the key
switch to the O
position and remove the key from the key switch.
FF
2. Unplug the 48V battery disconnect; refer to
5–4).
3. Disconnect the negative (–) battery cable from the 12V system battery; refer
to
Removing and Installing the 12V System Battery (Model 04580) (page
5–116).
4. Remove the exhaust system; refer to
4–10).
Figure 80
11.
12.
13.
14.
Removing the Exhaust System (page
Page 5–92
Isolating mount – front (2 each)
Cap screw (4 each)
Flat washer (3 each)
Cap screw (2 each)
48V Battery Disconnect (page