Toro Greensmaster eTriFlex 3360 Service Manual page 207

Hide thumbs Also See for Greensmaster eTriFlex 3360:
Table of Contents

Advertisement

Disassembling the Cutting Unit Motor
g289205
1.
Cap screw (12 each)
2.
Motor cover
3.
O-ring
4.
Wave washer (2 each)
5.
Bearing (2 each)
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev A
6.
Rotor
7.
Bearing (2 each)
8.
O-ring (2 each)
9.
Housing assembly
10.
O-ring
Note: If the motor housing, stator, controller or cable is damaged, cutting
reel motor replacement is necessary as these components are not available
separately.
Use of the cutting unit motor rotor tool part number TOR6028 is recommended
for this procedure; refer to
When servicing the cutting unit motor, use a clean work space with a
non-metal surface. The motor rotor includes very powerful magnets
that can cause the rotor to move unexpectedly if working on a metal
surface. Also, any metallic debris that gets attracted to the rotor can
damage the motor after assembly.
Refer to
Figure 90
for this procedure.
Figure 90
11.
12.
13.
14.
Cutting Unit Motor Rotor Tool (page
IMPORTANT
Page 5–109
Output gear
Gear box cover
Lip seal
O-ring
2–18).