Output signals (Pulse output) and its function
Name
Symbol
OA+
A phase output
OA-
OB+
B phase output
OB-
OZ+
Z phase output
OZ-
Z phase output
CZ
Analog monitor signals and their functions
Name
Symbol
Analog monitor output
Others
Name
Symbol
Frame ground
FG
Signal ground
GND
−
−
Connector
pin No.
21
22
Scaling processed encoder signal or external scale signal (A/B/Z-phase) is
output in differential mode. (RS422 equivalent)
48
Scaling ratio can be set by parameters.
The ground pin of the line driver on the output circuit is not insulated and is
connected to signal ground (GND).
49
The maximum output frequency is 8 Mpps (after quadrature).
23
24
Open collector output of Z-phase signal.
Ground of line driver of the output circuit is connected to signal ground
19
(GND); not insulated.
Connector
Pin No.
IM
42
Analog signal output for monitoring
Monitoring object changes according to the parameter setting.
SP
43
Connector
Pin No.
50,
Internally connected to the earth terminal.
shell
Signal ground
13,15,
Internally insulated from the control signal power supply (COM-).
17,25
Do not connect
20
No. SX-DSV03015 - 19 -
Description
Description
Description
Motor Business Unit, Panasonic Corporation
Circuit
Do-1
Do-2
Circuit
Ao-1
Circuit