9-3 Peripheral device configuration
9-3-1 Installation environment
Use the servo driver under the environment of pollution level 2 or 1 defined in IEC60664-1.
(Example: Installed in the IP54 control panel.)
100 V/200 V type
Power
Residual
supply
current
device
(RCD)
Metallic control box
Ferrite core
<Dedicated to power supply cable>
Circuit
Noise filter
breaker
Ferrite core
Surge
absorber
Insulated power
supply for interface
Ground (PE)
power supply cable>
Driver
L1
U
XB
XA
L2
V
L3
W
L1C
X6
L2C
X3
X4
Ferrite core
Controller
Motor Business Unit, Panasonic Corporation
No. SX-DSV03015 - 50 -
Ferrite core
<Dedicated to
Motor
M
RE
Ferrite core
Safety
controller