200 V size F
Power supply
(3-phase)
■Connection of regenerative resistor
Short bar
Size
(Accessories)
F
Supplied
-The standard of the ability of the built-in dynamic brake resistor is up
to continuousness three times in the stop from the allowance and maximum inertia and the rated speed.
Resistor is damaged and the dynamic brake might not work when using it under more critical operating condition.
- The circuit connected to terminal X1 – X6 are secondary circuits.
Insulation is needed against the primary side power supply (power supply of the motor brake).
Please do not connect them with the same power supply.
MCCB
Internal
regenerative
In case of using the external
resistor
regenerative resistor
Between RB and B:
Disconnect the short bar
Installed
Between P and B:
Connect the external
regenerative resistor
ON
OFF
L
MC
Short bar
External
regenerative
resistor
Red
White
Black
Green or
Green/Yellow
Motor
ALM
37
Insulated
+
DC12 to 24 V
36
-
(±5 %)
Connection of the connector XC
In case of not using the external
Between RB and B:
Connect the short bar
Motor Business Unit, Panasonic Corporation
No. SX-DSV03015 - 39 -
Built-in thermostat of an external
regenerative resistor (light yellow)
MC1
ALM
Coli surge suppression units
L1
Main power
L2
supply
L3
L1C
Control power
supply
L2C
P
RB
B
N
U
Motor
V
connection
W
X4
ALM+
ALM-
regenerative resistor