Mounting The Measuring Device - Endress+Hauser Liquiphant FTL33 IO-Link Operating Instructions Manual

Point level switch for liquids in the food sector
Hide thumbs Also See for Liquiphant FTL33 IO-Link:
Table of Contents

Advertisement

Installation
5.2

Mounting the measuring device

Use in accordance with WHG: Prior to mounting the device, pay attention to the WHG
approval documents. Documents available in the Downloads area of the Endress+Hauser
website:
www.endress.com → Downloads
5.2.1
Required tools
"Weld-in adapter accessories" thread
 10
"Weld-in adapter accessories" thread
1
Flat seal
2
Weld-in adapter
G ¾"
• L1: 63.9 mm (2.52 in)
• L2: 38.0 mm (1.5 in)
G 1"
• L1: 66.4 mm (2.61 in)
• L2: 48.0 mm (1.89 in)
Pressure and temperature (maximum):
+25 bar (+362 psi) at +150 °C (+302 °F)
+40 bar (+580 psi) at +100 °C (+212 °F)
When using a weld-in adapter with flush-mounted seal, the flat seal (1) supplied must
be removed from the thread.
18
32 mm
L1
L2
2
1
Liquiphant FTL33 IO-Link
A0023245
Endress+Hauser

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents