5.2

Mounting the measuring device

5.2.1

Required tools

Open-ended wrench or socket wrench 32 AF (socket wrench can be ordered as an
accessory →  50)
5.2.2

Installation

Horizontal installation in vessels
Use the marking to align the tuning fork in such a way that medium can run off easily and
deposit buildup is avoided.
The following types of marking are possible:
• As material specification (e.g.  316L) or as a thread designation (e.g.  G ½")
• On the hexagonal bolt of the process adapter
• On the weld-in adapter
• Marking (II) on the back of the flange
Correct alignment
±
Incorrect alignment
Installation in pipes
Correct alignment
Flow velocity up to 5 m/s with viscosity 1 mm
the function in the event of other process medium conditions.
<-1.4435
15°
2
/s (cSt) and density 1 g/cm
<-1.4435
<-1.4435
3
(SGU). Check
Installation
A0034850
A0037344
A0034851
15