Sign In
Upload
Manuals
Brands
Endress+Hauser Manuals
Switch
Liquiphant FTL62
Endress+Hauser Liquiphant FTL62 Manuals
Manuals and User Guides for Endress+Hauser Liquiphant FTL62. We have
6
Endress+Hauser Liquiphant FTL62 manuals available for free PDF download: Operating Instructions Manual, Brief Operating Instructions
Endress+Hauser Liquiphant FTL62 Operating Instructions Manual (60 pages)
Vibronic HART Point level switch with highly corrosion-resistant coating for liquids
Brand:
Endress+Hauser
| Category:
Switch
| Size: 1.51 MB
Table of Contents
Table of Contents
3
About this Document
6
Purpose of this Document
6
Symbols
6
Safety Symbols
6
Electrical Symbols
6
Tool Symbols
6
Communication-Specific Symbols
6
Symbols for Certain Types of Information
6
Symbols in Graphics
7
Registered Trademarks
7
Basic Safety Instructions
7
Requirements for the Personnel
7
Intended Use
7
Incorrect Use
8
Workplace Safety
8
Operational Safety
8
Product Safety
8
Functional Safety SIL (Optional)
9
IT Security
9
Device-Specific IT Security
9
Product Description
9
Product Design
10
Incoming Acceptance and Product
10
Identification
10
Incoming Acceptance
10
Product Identification
11
Nameplate
11
Manufacturer Address
11
Storage and Transport
11
Storage Conditions
11
Transporting the Device
11
Mounting
12
Mounting Requirements
12
Pay Attention to the Temperature for Devices with a PFA Coating (Conductive)
12
Take Switch Point into Consideration
13
Take Viscosity into Consideration
14
Avoid Buildup
15
Take Clearance into Consideration
15
Support the Device
16
Mounting the Device
16
Required Tool
16
Installation
17
Post-Mounting Check
19
Electrical Connection
19
Required Tool
19
Connecting Requirements
19
Cover with Securing Screw
19
Potential Equalization
20
Connecting the Device
20
Supply Voltage
21
Terminals
21
Cable Specification
21
4-20 Ma HART
21
Overvoltage Protection
21
Wiring
22
Terminal Assignment
23
Cable Entries
24
Available Device Plugs
24
Ensuring the Degree of Protection
24
Degree of Protection
24
Post-Connection Check
25
Operation Options
25
Overview of Operating Options
25
To 20 Ma HART (FEL60H) Electronic Insert
26
Function Test Using Operating Key on Electronic Insert
26
Structure and Function of the Operating Menu
27
User Roles and Related Access Authorization
27
Access to the Operating Menu Via the Local Display
28
Device Display (Optional)
28
Operation Via Bluetooth® Wireless Technology (Optional)
28
Access to the Operating Menu Via the Operating Tool
29
Historom Data Management
29
System Integration
30
Overview of Device Description Files
30
Measured Variables Via HART Protocol
30
Device Variables and Measured Values
30
System Units
31
Commissioning
31
Preliminaries
31
As-Delivered State
31
Function Check
31
Switching on the Device
31
Establishing a Connection Via Fieldcare and Devicecare
32
Via HART Protocol
32
Fieldcare/Devicecare Via Service Interface (CDI)
32
Configuring the Device Address Via Software
32
Setting the Operating Language
33
Local Display
33
Fieldcare
33
Devicecare
33
Device Configuration
34
Commissioning with DIP Switch and Operating Keys on the Electronic Insert
34
Resetting the Password or Device Via Operating Keys
34
Commissioning with "Commissioning" Wizard
34
Storing the Oscillation Frequencies
35
Simulation
35
Protecting Settings from Unauthorized Access
35
Locking or Unlocking the Hardware
35
Locking or Unlocking the Display Operation
36
Parameter Configuration - Locking or Enabling
36
Operation
37
Reading off the Device Locking Status
37
Reading off Measured Values
37
Adapting the Device to Process Conditions
37
Level Limit Detection
37
Sensor Frequency
37
Heartbeat Technology (Optional)
38
Heartbeat Verification
38
Heartbeat Verification/Monitoring
38
Proof Testing for SIL/WHG Devices (Optional)
38
Diagnostics and Troubleshooting
39
General Troubleshooting
39
General Errors
39
Error - Smartblue Operation with Bluetooth
40
Additional Tests
40
Behavior of Current Output in the Event of a Fault
41
Diagnostic Information on Local Display
41
Diagnostic Message
41
Diagnostic Event in the Operating Tool
42
Adapting the Diagnostic Information
43
Queued Diagnostic Messages
43
Diagnostic List
43
Event Logbook
45
Event History
45
Filtering the Event Logbook
45
Overview of Information Events
46
Resetting the Device
46
Resetting the Device Via the Operating Software or Display
46
Resetting the Device Via Operating Keys on the Electronic Insert
47
Device Information
47
11.10 Firmware History
47
11.10.1 Version 01.00.Zz
47
Maintenance
47
Maintenance Tasks
47
Cleaning
47
Repair
48
General Notes
48
Repair Concept
48
Repair of Ex-Certified Devices
48
Spare Parts
48
Replacement
48
Historom
49
Return
49
Disposal
49
Accessories
49
Device Viewer
49
Weather Protection Cover for Dual Compartment Housing
49
Weather Protection Cover for Single Compartment Housing, Aluminum
50
Plug-In Jack
50
Technical Data
51
Input
51
Measured Variable
51
Measuring Range
51
Output
51
Output Signal
51
Signal on Alarm
52
Load
52
Damping
52
Switch Output
53
Ex Connection Data
53
Protocol-Specific Data
53
Wireless HART Data
54
Heartbeat Technology
54
Environment
54
Ambient Temperature Range
54
Storage Temperature
55
Humidity
55
Operating Height
55
Climate Class
55
Degree of Protection
55
Vibration Resistance
56
Shock Resistance
56
Mechanical Load
56
15.3.10 Pollution Degree
56
Electromagnetic Compatibility
56
(Emc)
56
Process
56
Process Temperature Range
56
Thermal Shock
57
Process Pressure Range
57
Test Pressure
57
State of Aggregation
57
Medium Density
57
Viscosity
58
Pressure Tightness
58
Solids Contents
58
Additional Technical Data
58
Index
59
Advertisement
Endress+Hauser Liquiphant FTL62 Operating Instructions Manual (60 pages)
Vibronic Point level switch with highly corrosion-resistant coating for liquids
Brand:
Endress+Hauser
| Category:
Switch
| Size: 1.88 MB
Table of Contents
Table of Contents
3
About this Document
5
Purpose of this Document
5
Symbols
5
Safety Symbols
5
Electrical Symbols
5
Tool Symbols
5
Symbols for Certain Types of Information
5
Symbols in Graphics
6
Registered Trademarks
6
Basic Safety Instructions
6
Requirements for the Personnel
6
Intended Use
6
Incorrect Use
6
Workplace Safety
7
Operational Safety
7
Product Safety
7
Functional Safety SIL (Optional)
7
Security
7
Product Description
8
Product Design
8
Incoming Acceptance and Product
8
Identification
8
Incoming Acceptance
8
Product Identification
9
Nameplate
9
Electronic Insert
9
Manufacturer Address
9
Storage and Transport
9
Storage Conditions
9
Transporting the Device
10
Mounting
10
Mounting Requirements
11
Pay Attention to the Temperature for Devices with a PFA Coating (Conductive)
11
Take Switch Point into Consideration
12
Take Viscosity into Consideration
12
Avoid Buildup
13
Take Clearance into Consideration
14
Support the Device
14
Mounting the Device
15
Required Tool
15
Installation
15
Post-Mounting Check
16
Electrical Connection
17
Required Tool
17
Connecting Requirements
17
Cover with Securing Screw
17
Connecting Protective Earth (PE)
17
Connecting the Device
17
2-Wire AC (Electronic Insert FEL61)
18
3-Wire DC-PNP (Electronic Insert FEL62)
20
Universal Current Connection with Relay Output (Electronic Insert FEL64)
23
DC Connection, Relay Output (Electronic Insert FEL64 DC)
25
PFM Output (Electronic Insert FEL67)
27
2-Wire NAMUR > 2.2 Ma/ < 1.0 Ma (Electronic Insert FEL68)
29
LED Module VU120 (Optional)
31
Bluetooth Module VU121 (Optional)
33
Connecting the Cables
34
Post-Connection Check
35
Operation Options
36
Overview of Operation Options
36
Operating Concept
36
Elements on the Electronic Insert
36
Heartbeat Diagnostics and Verification with Bluetooth® Wireless Technology
36
LED Module VU120 (Optional)
37
Commissioning
37
Function Check
37
Functional Test Using Key on Electronic Insert
37
FEL61 Switching Behavior and Signaling
38
FEL62 Switching Behavior and Signaling
39
FEL64, FEL64DC Switching Behavior and Signaling
39
FEL67 Switching Behavior and Signaling
39
FEL68 Switching Behavior and Signaling
41
Functional Test of the Electronic Switch with a Test Magnet
41
Switching on the Device
41
Establishing a Connection Via Smartblue App
42
Prerequisites
42
Preparatory Steps
42
Smartblue App
42
Operation
44
"Diagnostics" Menu
44
Application" Menu
44
System" Menu
45
Heartbeat Verification
46
Proof Testing for SIL/WHG Devices
46
Diagnostics and Troubleshooting
47
Diagnostic Information Via Light Emitting
47
Diodes
47
LED at Electronic Insert
47
Smartblue
47
Firmware History
48
Maintenance
48
Maintenance Tasks
48
Cleaning
48
Repair
48
General Notes
48
Repair Concept
48
Repair of Ex-Certified Devices
49
Spare Parts
49
Return
49
Disposal
49
Battery Disposal
49
Accessories
50
Device Viewer
50
Test Magnet
50
Weather Protection Cover for Dual Compartment Housing, Aluminum
50
Protective Cover for Single Compartment Housing, Aluminum or 316L
51
Plug-In Jack
51
Bluetooth Module VU121 (Optional)
52
LED Module VU120 (Optional)
52
Technical Data
53
Input
53
Measured Variable
53
Measuring Range
53
Output
53
Output and Input Variants
53
Output Signal
54
Ex Connection Data
54
Environment
55
Ambient Temperature Range
55
Storage Temperature
56
Humidity
56
Operating Altitude
56
Climate Class
56
Degree of Protection
56
Vibration Resistance
56
Shock Resistance
56
Mechanical Load
56
14.3.10 Pollution Degree
56
14.3.11 Electromagnetic Compatibility
57
Process
57
Process Temperature Range
57
Thermal Shock
57
Process Pressure Range
57
Test Pressure
57
Density
58
Viscosity
58
Pressure Shocks
58
Pressure Tightness
58
Solids Contents
58
Additional Technical Data
58
Index
59
Endress+Hauser Liquiphant FTL62 Operating Instructions Manual (56 pages)
Vibronic Point level switch with highly corrosion-resistant coating for liquids
Brand:
Endress+Hauser
| Category:
Switch
| Size: 2.08 MB
Table of Contents
Table of Contents
3
1 About this Document
5
Symbols
5
Safety Symbols
5
Electrical Symbols
5
Symbols for Certain Types of Information
5
Symbols in Graphics
5
Registered Trademarks
6
2 Basic Safety Instructions
6
Requirements for the Personnel
6
Designated Use
6
Incorrect Use
6
Workplace Safety
7
Operational Safety
7
Product Safety
7
IT Security
7
3 Product Description
7
Product Design
8
4 Incoming Acceptance and Product
8
Identification
8
Incoming Acceptance
8
Product Identification
9
Nameplate
9
Manufacturer Address
9
Storage and Transport
9
Storage Conditions
9
Transporting the Device
10
5 Installation
10
Installation Conditions
11
Pay Attention to the Temperature for Devices with a PFA Coating (Conductive)
11
Take Switch Point into Consideration
11
Take Viscosity into Consideration
12
Avoid Buildup
13
Take Clearance into Consideration
13
Support the Device
14
Mounting the Measuring Device
14
Required Tool
14
Installation
15
Post-Installation Check
16
6 Electrical Connection
16
Connection Conditions
16
Cover with Securing Screw
16
Connecting Protective Earth (PE)
16
Connecting the Measuring Device
17
2-Wire AC (Electronic Insert FEL61)
17
3-Wire DC-PNP (Electronic Insert FEL62)
19
Universal Current Connection with Relay Output (Electronic Insert FEL64)
21
DC Connection, Relay Output (Electronic Insert FEL64 DC)
23
PFM Output (Electronic Insert FEL67)
25
2-Wire NAMUR > 2.2 Ma/ < 1.0 Ma (Electronic Insert FEL68)
27
LED Module VU120 (Optional)
28
Bluetooth Module VU121 (Optional)
30
Connecting the Cables
31
Post-Connection Check
31
7 Operation Options
32
Overview of Operation Options
32
Operating Concept
32
Functional Test Using the Button on the Electronic Insert
32
Functional Test of the Electronic Switch with a Test Magnet
35
Heartbeat Diagnosis and Verification
36
LED Module VU120 (Optional)
37
Commissioning
37
Establishing a Connection Via Smartblue (App)
37
Requirements
37
Preparatory Steps
38
Establishing a Connection Via Smartblue (App)
38
Function Check
37
Switching on the Measuring Device
37
9 Operation
39
"Diagnostics" Menu
39
Application" Menu
39
System" Menu
40
Heartbeat Verification
41
Proof Testing for SIL/WHG Devices
41
10 Diagnostics and Troubleshooting
42
Diagnostic Information Via Light Emitting
42
Diodes
42
LED at Electronic Insert
42
Smartblue
42
11 Maintenance
43
Maintenance Tasks
43
Cleaning
43
12 Repair
43
General Information
43
Repair Concept
43
Repair of Ex-Certified Devices
44
Spare Parts
44
Return
44
Disposal
44
Battery Disposal
44
13 Accessories
45
Test Magnet
45
Weather Protection Cover for Dual-Compartment Housing, Aluminum
45
Protective Cover for Single Compartment Housing, Aluminum or 316L
45
Plug-In Jack
46
Bluetooth Module VU121 (Optional)
47
LED Module VU120 (Optional)
47
14 Technical Data
48
Input
48
Measured Variable
48
Measuring Range
48
Output
48
Output and Input Variants
48
Output Signal
49
Ex Connection Data
49
Environment
49
Ambient Temperature Range
49
Storage Temperature
50
Humidity
50
Operating Altitude
50
Climate Class
50
Degree of Protection
50
Vibration Resistance
51
Shock Resistance
51
Mechanical Load
51
14.3.10 Electromagnetic Compatibility
51
Process
51
Process Temperature Range
51
Thermal Shock
51
Process Pressure Range
52
Test Pressure
52
State of Aggregation
52
Density
52
Viscosity
53
Pressure Shocks
53
Pressure Tightness
53
14.4.10 Solids Contents
53
14.4.11 Lateral Loading Capacity
53
Additional Technical Data
53
Advertisement
Endress+Hauser Liquiphant FTL62 Operating Instructions Manual (36 pages)
Vibronic Density measurement for liquids
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 1.36 MB
Table of Contents
Table of Contents
3
About this Document
5
Symbols
5
Safety Symbols
5
Electrical Symbols
5
Symbols for Certain Types of Information
5
Symbols in Graphics
5
Basic Safety Instructions
6
Requirements for the Personnel
6
Designated Use
6
Incorrect Use
6
Workplace Safety
6
Operational Safety
6
Product Safety
7
IT Security
7
Product Description
7
Liquiphant FTL62 Product Design
8
Incoming Acceptance and Product
8
Identification
8
Incoming Acceptance
8
Product Identification
9
Liquiphant Nameplate
9
Manufacturer Address
9
Storage and Transport
9
Storage Conditions
9
Transporting the Device
10
Installation
11
Installation Conditions
11
Installation in Pipes
12
Correction Factor
12
Avoid Buildup
14
Take Clearance into Consideration
15
Support the Device
15
Mounting the Measuring Device
16
Required Tool
16
Installation
16
Post-Installation Check
17
Electrical Connection
18
Connection Conditions
18
Cover with Securing Screw
18
Connecting Protective Earth (PE)
18
Connecting the Measuring Device
18
2-Wire Density (Electronic Insert FEL60D) for Density Measurement
18
Connecting the Cables
21
Post-Connection Check
22
Operation Options
23
Overview of Operation Options
23
Operation Concept
23
Elements on the Electronic Insert
23
Commissioning
23
Function Check
23
Powering up the Measuring Device
23
Operation
24
Light Signals
24
Diagnostics and Troubleshooting
24
Diagnostic Information Via Light Emitting
24
Diodes
24
LED at Electronic Insert
24
Maintenance
25
Maintenance Tasks
25
Cleaning
25
Repair
25
General Information
25
Repair Concept
25
Repair of Ex-Certified Devices
25
Spare Parts
26
Return
26
Disposal
26
Accessories
26
General
26
Extension Cards
27
PROFINET® Interface
27
Weather Protection Cover for Dual-Compartment Housing, Aluminum
27
Protective Cover for Single Compartment Housing, Aluminum or 316L
28
Additional Accessories
28
Technical Data
28
Input
28
Measured Variable
28
Measuring Range
28
Output
29
Output and Input Variants
29
Ex Connection Data
29
Environment
29
Ambient Temperature Range
29
Storage Temperature
29
Humidity
29
Operating Altitude
29
Climate Class
29
Degree of Protection
29
Vibration Resistance
30
Shock Resistance
30
Mechanical Load
30
14.3.10 Electromagnetic Compatibility
30
Process
30
Process Temperature Range
30
Thermal Shock
30
Process Pressure Range
30
Pressure Tightness
31
Additional Technical Data
31
Index
32
Endress+Hauser Liquiphant FTL62 Brief Operating Instructions (37 pages)
Vibronic Point level switch with highly corrosion-resistant coating for liquids
Brand:
Endress+Hauser
| Category:
Switch
| Size: 1.05 MB
Table of Contents
Associated Documentation
2
About this Document
2
Basic Safety Instructions
4
Product Safety
5
Incoming Acceptance and Product Identification
5
Product Identification
6
Storage and Transport
6
Mounting Requirements
7
Mounting the Device
11
Electrical Connection
13
Required Tool
13
Connecting the Device
14
Current Consumption
15
Connectable Load
15
Terminal Assignment
15
Power Consumption
30
Operation Options
32
Operating Concept
32
Switching on the Device
35
Endress+Hauser Liquiphant FTL62 Brief Operating Instructions (32 pages)
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 1.02 MB
Advertisement
Related Products
Endress+Hauser Liquiphant FTL64
Endress+Hauser Liquiphant M/S
Endress+Hauser Liquiphant
Endress+Hauser Liquiphant FTL62 Density
Endress+Hauser Liquiphant M/S with electronic Insert FEL56
Endress+Hauser Liquiline CSX series
Endress+Hauser Liquipoint T Series
Endress+Hauser Liquistation CSF Series
Endress+Hauser Liquiport 2000
Endress+Hauser LT5-6
Endress+Hauser Categories
Measuring Instruments
Transmitter
Radar
Switch
Accessories
More Endress+Hauser Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL