Mounting
14
5.2

Mounting the device

5.2.1

Required tool

• Open-ended wrench for sensor installation
• Allen key for housing locking screw
5.2.2

Installation

Aligning the tuning fork using the marking
The tuning fork can be aligned using the marking in such a way that the medium drains
off easily and buildup is avoided.
Markings are labeled on the process connection by means of:
Material specification, thread designation, circle, line or double line
 11
Position of the tuning fork when installed horizontally in the vessel using the marking
Installing the device in piping
• Flow velocity up to 5 m/s with a viscosity of 1 mPa⋅s and density of 1 g/cm³ (62.4 lb/ft³)
(SGU).
Check for correct functioning in the event of other process medium conditions.
• The flow will not be significantly impeded if the tuning fork is correctly aligned and the
marking is pointing in the direction of flow.
• The marking is visible when installed.
 12
Installation in pipes (take fork position and marking into consideration)
Screwing in the device
• Turn by the hex bolt only, 15 to 30 Nm (11 to 22 lbf ft)
• Do not turn at the housing!
Liquiphant FTL63
A0039125
A0034851
Endress+Hauser