3-15.
PREVENTIVE
MAINTENANCE
(CONT.)
Figure 1
Figure 2
Oct. 2012
INSPECT COUNTER-WEIGHT CABLES-ANNUALLY
Henny Penny 8 head fryers use two cables in the counter-weight
mechanism that helps in the raising and lowering of the lid.
Cables should be visually inspected yearly, either as part of a
planned maintenance program or during a routine service call.
Cables more than 10 years old should be replaced regardless of
inspection results.
If lid becomes difficult to operate, stop using the fryer
and call for service. Cables need replaced.
1.
Using a 3/8" socket, remove the 6 keps nuts around exterior
of rear cover, shown in Figure 1.
2.
Lift up on the rear cover and pull out at the bottom to clear
threaded studs. Figure 2. (Removing top shroud makes it
easier to remove the rear cover, but is not necessary.)
View of the counter-weights
with cover removed