Henny Penny OFE-391 Operator's Manual page 17

Open fryer
Table of Contents

Advertisement

GAS PIPING
MINIMUM PULL of equipment
away from wall permissible
for accessibility to Quick
Disconnect Device
DISCONNECT
BEFORE
MAXIMUM PULL
MINIMUM PULL FOR
ACCESSIBILITY
ONLY
Couplings and hose should
be installed in the same
plane as shown at left. DO
NOT OFFSET
COUPLINGS -- this causes
torsional twisting and
undue strain causing
premature failure
This is the correct way to
install metal hose vor
vertical traverse. Note the
single, natural loop.
Allowing a sharp bend, as
shown at right, strains and
twists the metal hose to a
point of early failure at the
coupling
Maintain the minimum or
larger bending diameter
between the couplings for
longest life.
Closing in the diameter at
the coupling, as shown at
right, creates double bends
causing work work fatigue
failure of the fittings.
In all installations where
"self-draining" is not
necessary, connect metal
hose in a vertical loop.
DO NOT CONNECT
METAL HOSE
HORIZONTALLY...unless
"self-draining" is necessary,
then use support on lower
plane as shown at left.
Dec. 2016
AVOID SHARP BENDS AND KINKS when
pulling equipment away from wall. (Maximum
pull will kink ends, even if installed properl y ,
and reduce Connector life.)
QUICK DISCONNECT
DEVICE still attached
while extended at
maximum pull
STRESS
STRESS
POINTS
POINTS
MAXIMUM PULL NOT
ADVISED WHILE
CONNECTED
10
CABLE RESTRAINT
Please refer to the illustration below
when installing cable restraint on all
moveable gas fryers.
I-bolt is to be secured to the building
using acceptable building contruction
practices.
DRY WALL CONSTRUCTION
Secure I-bolt to a building stud DO
NOT attach to dry wall only. Also,
locate the I-bolt at teh same height as
the gas service. Preferred installation
is approximately six inches to either
side of service. Cable restraint must
be at least six inches shorter than
flexible gas line.
Utilize elbows when necesary to avoid
sharp kinks or excessive bending. For
ease of movement, install with a
"lazy" loop. gas appliance must be
disconnected prior to maximum
movement. (Minimum movement is
permissible for hose disconnection).
12160004

Advertisement

Table of Contents
loading