Assembly And Installation; Ventilation Of The Spray Booth - WAGNER EvoMotion 40-15 Original Operating Manual

Piston pump. flow rate 15 cm
Table of Contents

Advertisement

VERSION 12/2015
OPERATING MANUAL
6.4

ASSEMBLY AND INSTALLATION

Note:
This pump can be used as part of a spraying system for Airless or AirCoat applications. Individual supplement
components for this pump can be found in the Wagner Accessories Catalogue, or can be put together with
the Spraypack Confi gurator. The nozzles must be selected according to the gun instructions. In the case of
spraypack orders, the pump (1) is already pre-mounted on a trolley (6) or on a frame at the factory.
Procedure:
1
Mount pump (1) on frame, trolley (6) or wall mount.
2
Mount an AirCoat system with the pressure regulator (7) and secure the thread at the air inlet to the
pump (1) with Loctite 270.
3
Mount suction system (5).
4
Mount the return valve (8) for pressure relief or product circulation.
5
Mount return tube (4) or return hose.
6
Connect the high-pressure hose (2) and gun (3) in accordance with the gun operating manual.
Example:
Airless system
3
1
2
8
4
5
6.4.1

VENTILATION OF THE SPRAY BOOTH

Observe the safety instructions in Chapter 4.1.3.
Operate the device in a spray booth approved for the working materials.
– or –
Operate the device on an appropriate spraying wall with the ventilation (extraction)
switched on.
Observe national and local regulations for the exhaust air speed.
ORDER NUMBER DOC2333558
3
6
B_04076
Example:
AirCoat system
7
1
2
8
4
5
6
B_04077
28