Cleaning And Maintenance; Cleaning; Cleaning Staff; Safety Instructions - WAGNER EvoMotion 40-15 Original Operating Manual

Piston pump. flow rate 15 cm
Table of Contents

Advertisement

VERSION 12/2015
OPERATING MANUAL
8

CLEANING AND MAINTENANCE

8.1

CLEANING

8.1.1

CLEANING STAFF

Cleaning work should be undertaken regularly and carefully by qualifi ed and trained staff .
They should be informed of specifi c hazards during their training.
The following hazards may arise during cleaning work:
- Health hazard from inhaling solvent vapors
- Use of unsuitable cleaning tools and aids
8.1.2

SAFETY INSTRUCTIONS

Clean the piston pump only with a damp cloth.
Observe safety instructions in Chapter 4.
Incorrect maintenance/repair!
Danger to life and equipment damage.
ORDER NUMBER DOC2333558
DANGER
Only a WAGNER service center or a suitably trained person may
carry out repairs and replace parts.
Only repair and replace parts that are listed in the "Spare parts"
chapter and that are assigned to the unit.
Before all work on the device and in the event of work
interruptions:
- Relieve pressure from spray guns and devices.
- Secure spray guns against actuation.
- Switch off the energy/compressed air supply.
- Disconnect the control unit from the mains.
Observe the operating and service manual for all work.