Grounding - WAGNER EvoMotion 40-15 Original Operating Manual

Piston pump. flow rate 15 cm
Table of Contents

Advertisement

VERSION 12/2015
OPERATING MANUAL
6.5

GROUNDING

Discharge of electrostatically charged components in
atmospheres containing solvents!
Explosion hazard from electrostatic sparks.
Heavy paint mist if grounding is insuffi cient!
Danger of poisoning.
Insuffi cient paint application quality.
Grounding scheme (example)
B_00304
Cable cross sections
Pump
Product tank
ORDER NUMBER DOC2333558
WARNING
Clean the piston pump only with a damp cloth.
Ground all device components.
Ground the work pieces to be coated.
WARNING
Ground all device components.
Ground the work pieces to be coated.
Paint tank
Floor, static dissipative
4 mm2;
6 mm2;
Conveyor
Work piece
R max < 1 M
Conveyor
16 mm2;
Booth
16 mm2;
Spraying stand
16 mm2;
Spraying stand
29