Identification; Explosion Protection Identification - WAGNER EvoMotion 40-15 Original Operating Manual

Piston pump. flow rate 15 cm
Table of Contents

Advertisement

VERSION 12/2015
OPERATING MANUAL
3

IDENTIFICATION

3.1

EXPLOSION PROTECTION IDENTIFICATION

As defi ned in Directive 94/9/EC (ATEX 95), the device is suitable for use in potentially
explosive areas.
CE
CE mark (European Communities)
Explosion-proof equipment
II
Device class II (not mining)
2
Category 2 device (suitable for zone 1)
G
Ex-atmosphere gas
c
Constructional security
IIB
Device class (Gas) IIB
T3
Temperature class T3: maximum surface temperature 200 °C; 392 °F
T4
Temperature class T4: maximum surface temperature 135 °C; 275 °F
X
Special instructions exist for safe operation.
Chapter "Identifi cation X".
3.2
IDENTIFICATION X
Maximum surface temperature
The maximum surface temperature of the piston pump can be reached if it runs dry.
Ensure that the piston pump is fi lled with suffi cient working or fl ushing agent.
Ensure that the separating agent tank is fi lled with suffi cient separating agent.
Temperature class T3: No dry running protection
Temperature class T4: With dry running protection
Ignition temperature
Ensure that the ignition temperature of the surrounding gases (pumping product,
cleaning agents) is higher than the maximum permitted surface temperature of the
device.
Ambient temperature
The permissible ambient temperature is: +5 °C to +50 °C; +41 °F to +122 °F.
Medium supporting atomizing
To atomize the product, use only weakly oxidizing gases, e.g., air.
ORDER NUMBER DOC2333558