Safety Instructions For Staff; Safe Handling Of Wagner Spray Devices - WAGNER EvoMotion 40-15 Original Operating Manual

Piston pump. flow rate 15 cm
Table of Contents

Advertisement

VERSION 12/2015
OPERATING MANUAL
Ensure that during spraying, persons wear static dissipative gloves. The grounding
takes place via the spray gun handle.
Protective clothing, including gloves, must comply with EN 1149-5. The measured
insulation resistance must not exceed 100 megohms.
Ensure that there are no ignition sources such as naked fl ames, sparks, glowing wires,
or hot surfaces in the vicinity. Do not smoke.
Ensure that the pipe joints, hoses, equipment parts and connections are permanently,
technically leak-proof:
- Periodic preventative maintenance and service (replacing hoses, checking tightness
strength and connections etc.).
- Regular monitoring of leaks and defects via visual inspection and odor testing, e.g.,
daily before commissioning, at the end of work or weekly.
In the event of defects, immediately bring the device or system to a stop and arrange
to have repairs carried out immediately.
Grounding
Make sure that the ground and potential equalization of all system parts are performed
reliably and continuously and can withstand the expected stress (e.g., mechanical
stress, corrosion).
4.2

SAFETY INSTRUCTIONS FOR STAFF

Always follow the information in this manual, particularly the general safety instructions
and the warning instructions.
Always follow local regulations concerning occupational safety and accident
prevention.
In electrostatics application: Anyone fi tted with a pacemaker must not enter the high-
voltage area!
4.2.1

SAFE HANDLING OF WAGNER SPRAY DEVICES

The spray jet is under pressure and can cause dangerous injuries.
Avoid injection of paint or fl ushing agents:
Never point the spray gun at people.
Never reach into the spray jet.
Before all work on the device, in the event of work interruptions and functional faults:
- Relieve pressure from spray guns and devices.
- Secure spray guns against actuation.
- Switch off the energy/compressed air supply.
- Disconnect the control unit from the mains.
- In the event of functional faults, remedy the fault as described in the "Troubleshooting"
chapter.
ORDER NUMBER DOC2333558