Regular Maintenance Work; Filling Separating Agent - WAGNER EvoMotion 40-15 Original Operating Manual

Piston pump. flow rate 15 cm
Table of Contents

Advertisement

VERSION 12/2015
OPERATING MANUAL
8.2.3

REGULAR MAINTENANCE WORK

1. Check the level of separating agent in the separating agent cup every day, and top
up if necessary.
2. Check and clean the high-pressure fi lter every day or as required (see Chapter 8.2.8.).
3. Every shut down should be carried out as laid down in Chapter 8.1.3!
4. Check hoses, pipes, and couplings every day and replace if necessary.
If the pump has to be emptied for maintenance work, proceed according to
Chapter 8.2.6.
The service manual is available in German and English.
For order number see Chapter 1.3.
8.2.4

FILLING SEPARATING AGENT

Piston pump dry run!
High wear/damage to the packings.
Paint or solvent can escape if the seals are dry.
Ensure that the separating fl uid tank is fi lled with suffi cient separating fl uid. Filling
level 1 cm; 0.4 inch under the cup edge.
Place the supplied separating agent into the separating agent cup.
Filling level:
1 cm; 0.4 inch under the cup edge.
Separating agent:
Order no. 9992504
Inclination angle of the pump
Maximum permissible inclination of pump for moving, transportation,
etc. after fi lling it with separating agent ± 30°.
The pump must be vertical during operation.
ORDER NUMBER DOC2333558
NOTICE
B_03918