15.7

Electrical connection

Electrical data S2Cb pump
15.8

Diaphragm rupture sensor

Contact (standard)
The electrical data do not relate to the motor, but the
pump, which is connected as a whole unit.
For the motor electrical data, use the motor data sheet
from our website www.prominent.com.
Identity code specification "power supply" - "U": 100 - 230 V ± 10%, 240 V
± 6%, 50/60 Hz
Data
Capacity
Max. starting current
Electrical data at 100 V
Data
Effective current
Switch on peak current, (for approx. 100
ms)
Electrical data at 230 V
Data
Effective current
Switch on peak current, (for approx. 100
ms)
* internal switchover
Fuses
Fuse
Value
Fuse, internal
6.3 AT - (1.5 kA)
Only use the original fuses from ProMinent! It is not suffi‐
cient to use a fuse with the above fuse rating.
Contact loading, max.
at voltage
Maximum current
30 V DC
1 A
The contact is an opener.
The contact is an potential-free.
Technical data
Value Unit
220 W
8.5 A
Value Unit
3.3 A
4 A
Value Unit
1.5 A
8 A
Order No.
732379
89