8.7.4 Security (SECURITY menu)

Main menu
Mode
Settings
Service
Information
Language
Continuous
display
8.7.4.1
Access protect.
To logout run through the menu above. Thereafter the HMI can be
removed from the pump.
Logging on takes place automatically whenever the HMI cable is con‐
nected to the CAN port.
If the HMI must be formally logged into: Logging on via the menu occurs in
exactly the same way as logging off.
If the HMI is disconnected from the CAN bus, without first logging it off, the
pump remains stationary.
WARNING!
An on/off switch may not be fitted on the pump,
dependent on the identity code and installation.
To be able to switch off the pump (to a zero-volts state)
independently from the entire installation (e.g. for repair),
use an electrical isolating device in the mains supply
cable, e.g. a mains switch or a plug / socket combina‐
tion. Clearly identify this isolating device as such.
Service
Clear counters
Display
HMI logout
Security
End
„SECURITY" menu, you can enter for which parts of the adjustment
In the
options an
„Access protect" should apply and a „password" be specified.
This menu itself is ALWAYS password protected.
As supplied the „password" is "1111".
In the first menu option, you can either set
„Lock menu" or „Lock all" :
„None" , to clear a set „Access protect" .
Select
n
„Lock menu" to lock the adjustment mode (point ① in the over‐
Select
n
view "Operating/setting diagram", in the appendix).
„Lock all" to lock the adjustment option for the directly adjust‐
Select
n
able variables in the continuous displays and to lock the stroke length
(point ② in the overview "Operating/setting diagram", in the appendix),
in addition to the adjustment mode.
Security
Access protect.
Password
End
„None" ( „Access protect" ) or
Setting
Access protect.
none
Lock menu
Lock all
Password
2683
61