Technical data
14.5.2

Media temperatures

PVT liquid end
SST liquid end
14.5.3

Air humidity

Air humidity
14.5.4

Enclosure rating and safety requirements

Degree of protection
Safety requirements
14.6

Electrical connection

Electrical data S2Cb pump
82
Data
Max. temperature long-term at max. oper‐
ating pressure
Max. temperature for 15 min at max. 2 bar
Minimum temperature
Data
Max. temperature long-term at max. oper‐
ating pressure
Max. temperature for 15 min at max. 2 bar
Minimum temperature
Data
Maximum air humidity *:
* non-condensing
Protection against contact and humidity:
IP 65 in accordance with IEC 529, EN 60529, DIN VDE 0470 Part 1
A CAN plug or the supplied sealing cap must always be
plugged into the CAN port for the HMI.
Degree of protection:
1 - mains power connection with protective earth conductor
The electrical data do not relate to the motor, but the pump,
which is connected as a whole unit.
For the motor electrical data use the motor data sheet in the
appendix.
Identity code specification "power supply" - "U": 100 - 230 V ± 10 %, 240 V
± 6 %, 50/60 Hz
Electrical data at 100 V
Value Unit
65 °C
100 °C
-10 °C
Value Unit
90 °C
120 °C
-10 °C
Value Unit
95 % rel.
humidity