Discharge Line; Electrical Connection - ProMinent vonTaine 1010 PP Assembly And Operating Instructions Manual

Solenoid-coupled centrifugal pump
Table of Contents

Advertisement

4.2.2 Discharge Line

4.3 Electrical connection

When designing pipes, fittings etc., make sure that the flow
n
resistance is as minimal as possible.
Make sure that the flow velocity does not exceed 1 m/s in the
n
suction line.
Make sure that the guide value for the flow velocity in the dis‐
n
charge line is 3 m/s.
You have to install a choke valve into the discharge line to reg‐
n
ulate the delivery flow.
Protect the motor with a motor protection switch.
n
Switch off the supply voltage a minimum of 5 minutes before
n
opening the terminal box.
Check whether the data on the nameplate matches the avail‐
n
able power supply.
Make sure that an electrician technician wires the electrical
n
connectors and provides the additional protection in accord‐
ance with the regional regulations and standards.
Arrangement/Installation
15