Application samples
The following hardware was used for the test configuration:
• TwinCAT master PC with Windows XP Professional SP 2, TwinCAT version 2.10 (Build 1305) and
INTEL PRO/100 VE Ethernet adapter
• Beckhoff Ethernet coupler terminal EK1100, terminals EL1012, EL6601 and EL9010
• Beckhoff Embedded PC CX9000 (subordinate control unit) with Windows CE v5.00, HW 1.4, terminals
EL2032, EL9010
Fig. 160: Integration of a lower-level control system
Configuration of the subordinate control system
For a connection with the TwinCAT master PC via the EL6601 the network address of the subordinate
control system has to be set according to the IP number range of the TwinCAT master PC subnet.
• From the desktop of the lower-level control system (Windows CE) choose Start -> Settings -> Network
and Dial-up Connections to start the configuration of the network settings
(You can also find information about setting the network address of a lower-level control system from
the Documentation on TwinCAT System Manager)