E.g.: Status Word Telegram Using Ppo Type 3 - Danfoss FC 300 Profibus Manual

Table of Contents

Advertisement

FC 300 Profibus

E.g.: Status Word Telegram using PPO Type 3

This example shows how the control word telegram relates to the PLC and the FC 300, using FC Control
Profile.
The control word telegram is sent from the PLC to the FC 300. PPO Type 3 is used in the example in order
to demonstrate the full range of modules. All the values shown are arbitrary, and are provided for the
purposes of demonstration only.
PCA
PIW:
256
Bit no.:
15
14
0
0
0
The table above indicates the bits contained within the statusword, and how they are presented as process
data in PPO type 3 for this example.
The following table indicates which bit functions, and which corresponding bit values are active for this
example.
Bit
Bit value = 0
00
Control not ready
01
Drive not ready
02
Coasting
03
No error
04
No error
05
Reserved
06
No error
07
No warning
08
Speed ≠
reference
09
Local operation
10
Outside
frequency range
11
No operation
12
Drive ok
13
Voltage ok
14
Torque ok
15
Timers ok
Function active
Function inactive
72
Application Examples
PCV
IND
PVA
258
260
262
master → slave
13
12
11
10
9
0
0
0
1
0
4
Bit value = 1
Control ready
Drive ready
Enable
Error (no trip)
Triplock
Warning
Speed = reference
Bus control
Within frequency range
In operation
Stopped, autostart
Voltage exceeded
Torque exceeded
Timers exceeded
MG.33.C2.02 - VLT is a registered Danfoss trademark
1
2
CTW
MRV
0F
07
20
00
264
266
STW
MAV
8
7
6
5
4
0
0
1
1
1
7
Bit value
1
1
1
Trip
0
0
-
0
0
0
1
1
1
1
0
0
0
0
PCD
3
4
5
6
PCD
PCD
PCD
PCD
268
270
272
274
3
2
1
0
1
1
0
0
C
7
0
F
0