FC 300 Profibus
PRO 6
PRO 7
PRO 8
Function:
Instead of using par. 9-15 and 9-16 to define
profibus telegrams freely, you can use standard
telegrams defined by the profibus profile. Standard
Telegram 1 equals to PPO type 3. This parameter is
automatically set to the according value (PPO type)
when the drive is configured by a PLC.
9-23 Parameters for Signals
Array [1000]
Option:
None
3-02 Minimum Reference
3-03 Maximum Reference
3-12 Catch Up/Slow Down Value
3-41 Ramp 1 Ramp Up Time
3-42 Ramp 1 Ramp Down Time
3-51 Ramp 2 Ramp Up Time
3-52 Ramp 2 Ramp Down Time
3-80 Jog Ramp Time
3-81 Quick Stop Ramp Rime
4-11 Motor Speed Low Limit
4-13 Motor Speed High Limit
4-16 Torque Limit Motor Mode
4-17 Torque Limit Generator Mode
8-90 Bus Jog 1 Speed
8-91 Bus Jog 2 Speed
16-00 Control Word
16-01 Reference [Unit]
16-02 Reference %
16-03 Status Word
16-05 Main Actual Value [%]
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor Voltage
16-13 Frequency
16-14 Motor Current
16-16 Torque
16-17 Speed [RPM]
16-18 Motor Thermal
16-19 KTY Sensor Temperature
16-20 Phase Angle
16-30 DC Link Voltage
16-32 Brake Energy / s
16-33 Brake Energy / 2 Min
16-34 Heatsink Temp.
16-35 Inverter Thermal
16-38 SL Controller State
16-39 Controlcard Temp.
62
Parameters
[106]
[107]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
Contains a list of signals you can enter in par.
[108]
9-15 and 9-16. Furthermore, it automatically
[108]
sets the parameters to meet the most common
[108]
requirements.
[108]
[108]
[108]
[108]
[108]
*
[108]
[108]
[108]
It is possible to edit parameters via Profibus, the
[108]
standard Interface, or the LCP. Disable editing via
[108]
Profibus with this parameter.
[108]
[108]
[108]
[108]
[108]
[108]
[108]
Process control (setting of Control Word, speed
[108]
reference, and process data) is possible via either
[108]
Profibus or the standard RS485 Interface but not
[108]
both at the same time. Local control is always
[108]
possible via the LCP. Control via process control is
[108]
possible with either terminals or bus depending on
[108]
the setting of par. 8-50 to 8-56.
[108]
MG.33.C2.02 - VLT is a registered Danfoss trademark
16-50 External Reference
16-51 Pulse Reference
16-52 Feedback [Unit]
16-53 Digi Pot Reference
16-60 Digital Input
16-61 Terminal 53 Switch Setting
16-62 Analog Input 53
16-63 Terminal 53 Switch Setting
16-64 Analog Input 54
16-65 Analog Output 42 [mA]
16-66 Digital Output [bin]
16-67 Freq. Input #29 [Hz]
16-68 Freq. Input #33 [Hz]
16-69 Pulse Output #27 [Hz]
16-70 Pulse Output #29 [Hz]
16-80 Fieldbus CTW 1
16-82 Fieldbus REF 1
16-84 Comm Option STW
16-85 FC Port CTW 1
16-90 Alarm Word
16-91 Alarm Word 2
16-92 Warning Word
16-93 Warning Word 2
16-94 Extended Status Word
16-95 Extended Status Word 2
Function:
9-27 Parameter Edit
Option:
Disabled
Enabled
Function:
9-28 Process Control
Option:
Disable
Enable cyclic master
Function:
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[108]
[0]
[1]
[0]
[1]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents