FC 300 Profibus
Bit 12, Relay 04
Bit 12 = "0" Relay 04 has not been activated. Bit 12 = "1" Relay 04 has been activated, provided Control
word bit 12 has been chosen in par. 5-40 Function relay.
Bit 13/14, Selection of set-up
Bits 13 and 14 are used to choose from the four
menu set-ups according to the following table:
The function is only possible when Multi-Set-ups is
selected in par. 0-10 Active Set-up.
NB!:
In par. 8-55 Set-up select a selection is made to define how Bit 13/14 gates with the corresponding
function on the digital inputs.
Bit 15 Reverse
Bit 15 = "0" causes no reversing.
Bit 15 = "1" causes reversing.
How to Control the FC 300
MG.33.C2.02 - VLT is a registered Danfoss trademark
Set-up
Bit 14
1
0
2
0
3
1
4
1
Bit 13
0
1
0
1
37