FC 300 Profibus
PROFIdrive profile
Function:
Selects the interpretation of the control and status
words. The installed option in slot A determines the
valid selection.
8-50 Coasting Select
Option:
Digital input
Bus
Logic AND
*
Logic OR
Function:
Allows a choice between controlling the coasting
function via the terminals (digital input) and/or via
the bus.
NB!:
This parameter is active only when par.
8-01 Control Site is set to [0] Digital and
control word.
8-51 Quick Stop Select
Option:
Digital input
Bus
Logic AND
*
Logic OR
Function:
Allows a choice between controlling the Quick stop
function via the terminals (digital input) and/or via
the bus.
NB!:
This parameter is active only when par.
8-01 Control Site is set to [0] Digital and
control word.
8-52 DC Brake Select
Option:
Digital input
Bus
Logic AND
*
Logic OR
Function:
Allows a choice between controlling the DC brake
via the terminals (digital input) and/or via the bus.
NB!:
This parameter is active only when par.
8-01 Control Site is set to [0] Digital and
control word.
Parameters
[1]
*
Choose between controlling the drive via the
[0]
terminals (digital input) and/or via the bus.
[1]
If you select Bus, you can only activate the
[2]
Start command if it is transmitted via the serial
[3]
communication port or fieldbus option. If you select
Logic AND, you must also activate the command via
one of the digital inputs. If you select Logic OR, you
can also activate the Start command via one of the
digital inputs.
[0]
[1]
[2]
*
[3]
Choose between controlling the drive via the
terminals (digital input) and/or via the bus.
If you select Bus, you can only activate the
Reversing command if it is transmitted via the serial
communication port or fieldbus option. If you select
Logic AND, you must also activate the command via
one of the digital inputs. If you select Logic OR,
you can also activate the Reversing command via
one of the digital inputs.
[0]
[1]
[2]
[3]
MG.33.C2.02 - VLT is a registered Danfoss trademark
8-53 Start Select
Option:
Digital input
Bus
Logic AND
Logic OR
Function:
NB!:
This parameter is active only when par.
8-01 Control Site is set to [0] Digital and
control word.
8-54 Reversing Select
Option:
Digital input
Bus
Logic AND
Logic OR
Function:
NB!:
This parameter is active only when par.
8-01 Control Site is set to [0] Digital and
control word.
[0]
[1]
[2]
[3]
[0]
[1]
[2]
[3]
59