LCC Fault Code Procedure (continued)
F5 E1

(Door Latch Switch)

Run Diagnostic Mode and verify
fault code
While in Diagnostic Mode - Start
Clean cycle, to verify door does latch.
Unplug range or disconnect power.
If door did not latch - check for
contunity at CON3-4 to CON3-1
If no contunity - check for 500-3000Ω
resistance at CON1-4 to CON1-1
If resistance check fails - replace
Latch motor.
If resistance check is good, check
door (slot) and latching rod
alignment.
If door alignment is good -
Replace Door Latch Switch