Electrical Shock Hazard
No Faults - Control is good do not replace
No Display - Control blank
MRC II Fault Code Procedure
3-
Eletrical Shock Hazard
Do Not Replace Control
• Verify voltage at power supply.
• Verify voltage between control
board pins P6-1 and P6-3 by
completing the following steps:
1. Unplug range or disconnect power.
2. Connect voltage measurement
equipment between control board
pins P6-1 and P6-3.
3. Plug in range or reconnect power
and confirm voltage reading.
4. Unplug range or disconnect power.
• If voltage check is good, replace
control board.
16