All F1 E* Codes
(Control)
F2 Fault Code (Stuck Key on Control)
F3 E0
(Sensor)
F3 E2 (Warming Drawer Sensor)
MRC Fault Code Procedure (continued)
2-
11
•
Run Diagnostic Mode and
go to "Faults" display
•
Verify fault code
•
Unplug range or disconnect
•
power.
•
Replace Control
•
Run Diagnostic Mode and go
to "Faults" display
•
Verify fault code
•
Unplug range or disconnect
power.
•
Check Ribbon Connector on
Control
•
If connector is good
Replace Control
•
Run Diagnostic Mode and go
to "Faults" display
•
Verify fault code
•
Unplug range or disconnect
power.
•
Check Sensor for 1000-1200
at P10-1 to P10-2
•
Check Sensor for short to
ground
•
If checks are not correct -
Replace Sensor
•
Run Diagnostic Mode and go
to "Faults" display
•
Verify fault code
•
Unplug range or disconnect
power.
•
Check Sensor for 1000-1200 Ω
at P10-3 to P10-4
•
Check Sensor for short to
ground
•
If checks are not correct -
Replace Sensor
Ω