MRC II Double Oven, True Convection (Lower), Gas

MRC II Control, Double Oven, True Convection (Lower), Gas
Press "OPTIONS" until "Temp Calib"
is displayed.
Press #3 or #6 keypads.
Press START.
Press CANCEL/CANCEL/START
Press the the number "3" key, follow
directions at each operation.
Press "3" again
When in the Diagnostic mode, instructions will be provided by the control to help you through
each of the programs. Press Cancel to exit the test at any time.
When checking for Fault Codes and "NO FAULTS" is displayed. Do Not replace the Control.
The "AUTO TEST" program will automatically test all the oven circuits. This test is very easy to
use and when the test is complete, test results will be provided. Whenever servicing the oven,
this is the test to run.
Temperature Adjustment
Previous Offset shown.
Adjusts temperature in 5⁰F (3⁰C) increments
between -30⁰F (-18⁰C) and +30⁰F (+18⁰C).
Bake and Broil Temperatures are offset
automatically to the same degree.
If START is not pressed within 1 minute,
adjustment is ignored.
Diagnostic Mode
Action
"TEST ON" ##⁰F "UO"
"CONTROL RESET"
"USAGE"
"3" again
"ENG MODE"
"3" again
"TEST MODE"
"3" again
"VERSION"
"3" again
"DISPLAY"
"3" again
"FAULTS"
"AUTO TEST"
"3" again
the OVEN, automatically)
*Press"DELAY START"
*Press "START TIME" to clear all fault codes.
Display
(Resets Control settings)
(Displays hours of Operation)
(Manufacturing Information)
(Manual Check of Control relays)
(Manufacturing Information)
(Checks all LEDs in Display)
*(Displays all Fault Codes)
(Performs a complete check of
14
3-
Models:
KGRS505XBL00
KGRS505XSS00
KGRS505XWH00
(In the test mode)