All F1 E* Codes
(Control)
F2 Fault Code (Stuck Key on Control)
All F3 E*
(Sensor)
F5 E0
F5 E2 (Door Switch)
LCC Fault Code Procedure (continued)
•
Run Diagnostic Mode and verify
fault code
•
Unplug range or disconnect power.
•
Replace Control
•
Run Diagnostic Mode and verify
fault code
•
Unplug range or disconnect power.
Replace Control
•
Run Diagnostic Mode and verify
fault code
•
Unplug range or disconnect power.
•
Check Sensor for 1000-1200 Ω at
CON3-9 to CON3-10
•
Check Sensor for short to ground
•
If checks are not correct -
Replace Sensor
•
Run Diagnostic Mode and
verify fault code
•
Unplug range or disconnect
power.
•
Check door switch for
continuity with door open and
door closed at CON3-4 to CON3-3
Door Open -Infinite Resistance
Door Closed - 0 resistance
•
If checks are not correct -
Replace Door Switch
1-
27