Lcc Fault Code Procedure; Voltage Measurement Safety Information; Clr/Good - Control Is Good Do Not Replace; No Display - Control Blank - Whirlpool AER5522VAS0 Manual

Freestanding gas and electric range controls troubleshooting guide
Table of Contents

Advertisement

Electrical Shock Hazard

CLr/Good - Control is good do not replace

No Display - Control Blank

LCC Fault Code Procedure

1-
Eletrical Shock Hazard
Verify voltage at power supply.
Verify voltage between control board
and terminal block by completing
the following steps:
1. Unplug range or disconnect power.
2. Connect voltage measurement
equipment to control board and
terminal block.
3. Plug in range or reconnect power
and confirm voltage reading.
4. Unplug range or disconnect power.
Verify voltage between CON 2-4 and
CON 1-1 by completing the following
steps:
1. Unplug range or disconnect power.
2. Connect voltage measurement
equipment to CON 2-4 and CON 1-1.
3. Plug in range or reconnect power
and confirm voltage reading.
If voltage checks are good, unplug
range or disconnect power and
replace control panel.