Stroke Sensor (Option), Intrinsically Safe; Filling Volumes; Gear Oil; Sound Pressure Level - ProMinent Makro/ 5 Operating Instructions Manual

Diaphragm metering pump
Table of Contents

Advertisement

15.7

Stroke sensor (option), intrinsically safe

Namur sensor (identity code specifica‐
tion "Stroke sensor": 1)
Namur sensor (Specified for EX
zones)
15.8

Filling volumes

15.8.1

Gear oil

15.9

Sound pressure level

Sound pressure level
Install the sensor according to the chapter "Installation,
electrical".
5–25 V DC, in accordance with Namur or DIN 19234, potential-free
design.
Data
Rated voltage *
Power consumption - active surface
uncovered
Power consumption - active surface
covered
Rated switching distance
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
Gear oil
Gear oil
Mobilgear 634 VG 460
Required amount of oil
Pump type
All:
Sound pressure level LpA < 75 dB in accordance with EN ISO
20361:2010-10
at maximum stroke length, maximum stroke rate, maximum back
pressure (water)
Value Unit
Supplied quantity
20.0 l
Oil change, compl.
16.5 l
Technical data
8 VDC
> 3 mA
< 1 mA
1.5 mm
Part no.
1006284