ProMinent Makro/ 5 Operating Instructions Manual page 22

Diaphragm metering pump
Table of Contents

Advertisement

Assembly
Supporting floor
h
P_MOZ_0016_SW
Fig. 10
Space requirement
A
A
P_MOZ_0018_SW
Fig. 11
1
f
f
f
3
P_MOZ_0017_SW
Fig. 12
22
Position the pump so that control elements such as the stroke
length adjustment knob, the indicating dial A or the oil inspection
window are accessible.
In so doing, ensure there is enough space to carry out an oil
change (vent screws, oil drain plugs, oil trough ...).
1
Discharge valve
2
Dosing head
2
3
Suction valve
Ensure there is sufficient free space (f) around the dosing head as
well as the suction and discharge valve so that maintenance and
repair work can be carried out on these components.
WARNING!
Risk of electric shock
If water or other electrically conducting liquids pene‐
trate into the drive housing, an electric shock may
occur.
Position the pump so that drive housing cannot be
flooded.
WARNING!
The pump can break through the supporting floor or
slide off it
The supporting floor must be horizontal, smooth
and permanently load-bearing.
Capacity too low
Vibrations can disturb the valves of the liquid end.
The supporting floor must not vibrate.
CAUTION!
Danger from incorrectly operated or inadequately
maintained pumps
Danger can arise from a poorly accessible pump due
to incorrect operation and poor maintenance.
Ensure that the pump is accessible at all times.
Adhere to the maintenance intervals.