14.5.2
Air humidity
14.6
Housing degree of protection
14.7
Stroke sensor (optional), intrinsically safe
Stroke sensor (option), intrinsically safe
Namur sensor (Specified for EX zones)
14.8
Diaphragm rupture sensor
Data
Maximum air humidity *:
*non-condensing (according to DIN IEC 60068-2-30)
Data
Protection against contact and humidity*
*according to DIN VDE 470 (EN IEC 60529)
Install the sensor according to the chapter "Installation, elec‐
trical".
5–25 V DC, in accordance with Namur or DIN 19234, potential-free
design.
Data
Rated voltage *
Power consumption - active surface
uncovered
Power consumption - active surface cov‐
ered
Rated switching distance
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
Install the sensor according to the chapter "Installation, elec‐
trical".
Technical data
Value Unit
95 % rel.
humidity
Value
IP 55
Value Unit
8 VDC
> 3 mA
< 1 mA
1.5 mm
57